+1 408 625-1090
PCI Power Systems Division
POWER SUPPLIES
PCI Power Systems designs, manufactures and supports a wide range of Power Supply Products
PCI_800.101
10-36V Continuous Input Voltage
2250V Isolation Between Input /Output
Input Holdup time 50msec min. at 200W
Active Input EMI Filtering
Transient look ahead/cut-off technology
4 Voltage output Rails • 250W Maximum Power
93% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
PCI_800.104
14-36V Continuous Input Voltage
NO Isolation Between Input /Output
Input Holdup time 50msec min. at 300W
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
700W Maximum Power
95% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
PCI_800.108
12-36VDC Continuous Input Voltage
2250V Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
2 Voltage output Rails, 28V and 3.3Vaux o 12V output optional
1000W Maximum Continuous Power
95% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.111
• 10-36VDC Continuous Input Voltage • 2250V Isolation Between Input /Output • Active Input EMI Filtering • Transient forward looking/cut-off technology • 2 Voltage output Rails, 12V and 3.3Vaux • 750W Maximum Continuous Power • 95% Typical Efficiency • -40°C to 85°C Rail Operating Temperature • VITA 62 3U Form Factor • VITA 46.11 ready • Patent pending FourRail thermal interface • [SMART.PSU] Technology
PCI_800.155
• 220VAC Continuous Input Voltage
• VITA 62.2 specification compatible
• 2300V Isolation Between Input /Output
• Active Input EMI Filtering
• Transient look ahead/cut-off technology
• 6 Voltage output Rails
• Isolated 3.3V aux standby feature
• 600W Maximum Power, NO PFC stage
• 92% Typical Efficiency
• -40°C to 85°C Rail Operating Temperature
• VITA 62 3U Form Factor
• VITA 46.11 ready
• Patent pending FourRail thermal interface
• [SMART.PSU] Technology
PCI_800.305
12-36VDC Continuous Input Voltage
2250V Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
6 Voltage output Rails
500W Maximum Continuous Power
Optional HoldUp circuitry, 400msec at 400W
92% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal
PCI_800.310
3 phase 115VAC 400Hz Continuous Input Voltage
40msec hold time at 600W
1500V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
660W Maximum Continuous Power
92% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
PCI_800.313
12-36VDC Continuous Input Voltage
2250V Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
6 Voltage output Rails
500W Maximum Continuous Power
Optional HoldUp circuitry, 400msec at 400W
92% Typical Efficiency • -40°C to 85°C Rail Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.316
1 phase 85-264VAC 50/60Hz/400Hz input
4240VDC Isolation Between Input /Output/Chassis
Active Input EMI Filtering
Transient look ahead/cut-off technology
5 Voltage output Rails
Isolated, independent 3.3V aux standby feature
1.200W Maximum Continuous Power, NO derating
87% Typical Efficiency
-55°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Active, DSP controlled, dual interleaved PFC input stage
1.6” pitch, FourRail™ thermal interfaces to the chassis walls (Patent Pending)
SMART internal feature managing functions
FiveNines (99.999%) reliability
VITA 62.2 High Voltage input pin separation
Completely digital controlled rails and functions
PCI_800.318
3 Phase 115V 400Hz Continuous Input Voltage
DSP based 3phase PFC input stage
Vita 62.2 High Voltage Input Connector
3500V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
1.800W Maximum Continuous Power
90% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.321
200V to 420V Continuous Input Voltage
Extended Voltage Safety VITA62.2 connectors
100msec hold time at 1000W (HOLD_UP stage internal)
4.200V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
12V Voltage Rail
Isolated 3.3V aux standby feature
2.400W Maximum Continuous Power
90% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
PCI_800.408
12-36V Continuous Input Voltage
250 msec hold up time at 25deg C at 500W
80 msec hold up time at -40deg C at 500W
NO Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
500W Maximum Power
96% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
Can be used for military or aviation purposes
PCI_800.450
1 phase 85-264VAC 50/60Hz input
2200VDC Isolation Between Input /Output/Chassis
Input EMI Filtering
Transient look ahead/cut-off technology
12V, 24V, 28V Voltage Output Options
700msec hold up, 12V/80A peak
600W Maximum Continuous Power, NO derating
87% Typical Efficiency
-40°C to 85°C Operating Temperature
1U Form Factor, 250mm deep
Rugged MIL-DTL-38999 connectors
IP65 rating
SMART internal feature managing functions
FiveNines (99.999%) reliability
PCI_800.917
+/- 70VDC Continuous Input/Output Voltage
Sixteen independent +/- channels at 15A, 20A max. each
Trip current and ON/OFF, trip reset capability for each channel
VITA 83 compliant Channel sequencing with user defined delays
Ethernet interface, Dual RS485 interfaces for control
Optional CANbus and MILbus 1553 interface
Dual Voltage (+/-) Tracking for each channel
Measurements of Input, output voltage, output current for each channel
Trip/Fault Status (if Over Current / Short Circuit)
Friendly WINDOWS based GUI to set up and monitor all system parameters
PCI_800.102
12-36V Continuous Input Voltage
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails, +/-12V aux optional
Isolated 3.3V aux standby feature optional
400W Maximum Power
92% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
PCI_800.105
12-36V Continuous Input Voltage (optional)
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails, 12V aux optional
Isolated 3.3V aux standby feature optional
400W Maximum Power
92% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
PCI_800.107
12V-40V wide Continuous Input Voltage
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
500W Maximum Power
NO derating up to 85 deg. C at the rail
93% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.109
10V-40V wide Continuous Input Voltage
380msec Hold Up at 400W
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
500W Maximum Power
NO derating up to 85 deg. C at the rail
93% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.116
220-290VDC Continuous Input Voltage
1800V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
600W Continuous Power
93% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.161
• 3 phase 115VAC 400Hz Continuous Input Voltage • 10msec hold time at 1200W • 1500V Isolation Between Input /Output • Active Input EMI Filtering • Transient look ahead/cut-off technology • 2 Voltage output Rails: +28V and +3.3Vaux o +12V optional instead of 28V • 1200W Maximum Continuous Power • 92% Typical Efficiency • -40°C to 85°C Operating Temperature • VITA 62 3U Form Factor • Patent pending FourRail thermal interface
PCI_800.165
• 3 phase 115VAC 400Hz Input Voltage • 150msec hold time • 28V backup input • 4000V Isolation Between Input /Output • Active Input EMI Filtering • No 3phase input filter inside the power supply • Transient look ahead/cut-off technology • 6 Voltage output Rails • 3 Phase DSP controlled Power Factor Correction • 900W Maximum Continuous Power, no derating • 89% Typical Efficiency • -40°C to 85°C Operating Temperature • VITA 62 3U Form Factor • Patent pending FourRail thermal interface • Space saving design combines Vita 62 and VITA 62.1 specification
PCI_800.306
1 phase 85-230VAC 50/60Hz input
150msec hold time at 380W
2150V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
5 Voltage output Rails
Isolated 3.3V aux standby feature
600W Maximum Continuous Power
92% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
PCI_800.311
115V 400HzContinuous Input Voltage
100msec hold time at 600W
2500V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
1200W Maximum Continuous Power
92% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
PCI_800.314
12-36VDC Continuous Input Voltage
2250V Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
6 Voltage output Rails
1000W Maximum Continuous Power
92% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal
PCI_800.316 air
1 phase 85-264VAC 50/60Hz/400Hz input
4240VDC Isolation Between Input /Output/Chassis
Active Input EMI Filtering
Transient look ahead/cut-off technology
5 Voltage output Rails
Isolated, independent 3.3V aux standby feature
1.200W Maximum Continuous Power, NO derating
87% Typical Efficiency
-55°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Active, DSP controlled, dual interleaved PFC input stage
1.6” pitch, FourRail™ thermal interfaces to the chassis walls (Patent Pending)
SMART internal feature managing functions
FiveNines (99.999%) reliability
VITA 62.2 High Voltage input pin separation
Completely digital controlled rails and functions
PCI_800.319
3 Phase 115V 400Hz Continuous Input Voltage
DSP based 3phase PFC input stage
Vita 62.2 High Voltage Input Connector
3500V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
1.200W Maximum Continuous Power
90% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.322
3 Phase 115V 50-400Hz Continuous Input Voltage
DSP based 3phase interleaved PFC input stages
Vita 62.2 High Voltage Input Connector
3500V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
3.600W Maximum Continuous Power
90% Typical Efficiency
40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.410
12-36V Continuous Input Voltage
700 msec hold up time at 25deg C at 500W
200 msec hold up time at -40deg C at 500W
NO Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
1000W Maximum Power
96% Typical Efficiency
-40°C to 85°C Operating Temperature • VITA 62 3U Form Factor
Patent pending FourRail thermal interface
Can be used for military or aviation purposes
PCI_800.915
28VDC Continuous Input Voltage
Nine independent channels
ON/OFF capability for each channel
Trip current capability for each channel
Trip Reset capability
Channel sequencing with user defined delays
Dual RS485 interfaces for control
Measurements of Input voltage, output voltage, output current for each channel
12-/16-Bit ADC with ± 0.7% Error
On board temperature of the Unit
Trip/Fault Status (if Over Current / Short Circuit)
Friendly GUI to set up and monitor
PCI_800.918
+/- 28VDC Continuous Input/Output Voltage
Sixteen independent channels at 25A max. each
Trip current and ON/OFF, trip reset capability for each channel
Channel sequencing with user defined delays,
Gigabit Ethernet interface
Optional CAN bus and MILbus 1553 interface
Measurements of Input, output voltage, output current for each channel
Trip/Fault Status (if Over Current / Short Circuit)
Build in Intel type COMe computer module
Friendly WINDOWS based GUI to set up and monitor all system parameters
PCI_800.103
12V-40V wide Continuous Input Voltage
9V-40V input optional
Designed for cPCI and VME upgrades
Voltage Rails sequencing programmable
VBAT - 400 microAmps source on board
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
5 Voltage output Rails, 80A at 5V
Isolated 3.3V aux standby feature
500W Maximum Power
NO derating up to 85 deg. C at the rail
93% Typical Efficiency
PCI_800.106
10V-40V wide Continuous Input Voltage
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
650W Maximum Power
NO derating up to 85 deg. C at the rail
94% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
PCI_800.107 air
12V-40V wide Continuous Input Voltage
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
500W Maximum Power
NO derating up to 85 deg. C at the rail
93% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.110
9V-40V wide Continuous Input Voltage
Hold Up 250W at 40 mSec at -40 deg. C. , 220 mSec at 25 deg. C.
2300V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
3 Voltage output Rails
Isolated +3.3Vaux voltage
250W Maximum Power
NO derating up to 85 deg. C at the rail
93% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
PCI_800.117
• 220-290VDC Continuous Input Voltage • 1800V Isolation Between Input /Output • Active Input EMI Filtering • Transient look ahead/cut-off technology • 4 Voltage output Rails for 12V centric systems • Isolated 3.3V aux standby feature • 850W Continuous Power • 93% Typical Efficiency • -40°C to 85°C Rail Operating Temperature • VITA 62 3U Form Factor • VITA 46.11 ready • Patent pending FourRail thermal interface • [SMART.PSU] Technology
PCI_800.163
1 phase 85-264VAC 50Hz or 270VDC Continuous Input Voltage
1500V Isolation Between Input /Output
•Active Input EMI Filtering
Transient look ahead/cut-off technology
28VDC output Rail
Isolated 3.3V aux standby feature
600W Maximum Continuous Power
88% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
Load sharing
PCI_800.170
3 phase 115VAC 400Hz Input Voltage
120msec hold time
Isolated separate 3.3V aux output
3000V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
28V output
3 Phase DSP controlled Power Factor Correction
1200W Maximum Continuous Power, no derating
89% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 3U Form Factor
Patent pending FourRail thermal interface
Space saving design combines Vita 62 and VITA 62.1 specification
PCI_800.307
18-36VDC Continuous Input Voltage
NO Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
5 Voltage output Rails
1200W Maximum Continuous Power
95% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.312
200V to 420V Continuous Input Voltage
150msec hold time at 660W
4200V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
6 Voltage output Rails
Isolated 3.3V aux standby feature
1200W Maximum Continuous Power
93% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
PCI_800.315
1 phase 85-264VAC 50/60Hz input
3000VDC Isolation Between Input /Output/Chassis
Active Input EMI Filtering
Transient look ahead/cut-off technology
5 Voltage output Rails
Isolated, independent 3.3V aux standby feature
700 Maximum Continuous Power, 87% Typical Efficiency
Active, DSP controlled, dual interleaved PFC input stage PF better than 0.98
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
1.6” pitch, FourRail™ thermal interfaces to the chassis walls (Patent Pending)
SMART internal feature managing functions
FiveNines (99.999%) reliability
VITA 62.2 High Voltage input pin separation
Completely digital controlled rails and functions
PCI_800.317
12-36VDC Continuous Input Voltage
2250V Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
2 Voltage output Rails
2000W Maximum Continuous Power
95% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.320
200V to 420V Continuous Input Voltage
Extended Voltage Safety VITA62.2 connectors
100msec hold time at 1200W (with external module)
4.200V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
12V or 28V output Voltage Rail
Isolated 3.3V aux standby feature
2.400W Maximum Continuous Power
93% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
PCI_800.323
3 Phase 115Vrms 47-440Hz Continuous Input Voltage
DSP based 3phase PFC input stages
Vita 62.2 High Voltage Input Connector
1500V Isolation Between Input /Output
Needs external input filtering
Transient look ahead/cut-off technology
5 Voltage output Rails • Provision for external hold-up capacitor
Isolated 3.3V aux standby feature
1.400W Maximum Continuous Power
90% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready with extra software
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.412
220-290VDC Continuous Input Voltage •
180 msec hold up time at 25deg C at 1800W
80 msec hold up time at -40deg C at 1800W
NO Isolation Between Input /Output
Transient look ahead/cut-off technology
1800W Maximum Power
96% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor •
Patent pending FourRail thermal interface
PCI_800.916
100VDC Continuous Input Voltage
Sixteen independent channels at 25A each
ON/OFF capability for each channel
Trip current capability for each channel
Trip Reset capability
Channel sequencing with user defined delays
Dual RS485 interfaces for control
Ethernet and MILbus interface
Optional CANbus interface
Measurements of Input voltage, output voltage, output current for each channel
12-/16-Bit ADC with ± 0.7% Error
On board temperature of the Unit
Trip/Fault Status (if Over Current / Short