+1 408 625-1090
PCI Power Systems Division
POWER SUPPLIES
SOSA
SOSA based power products are build using tha latest SOSA standards.
PCI_800.108
12-36VDC Continuous Input Voltage
2250V Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
2 Voltage output Rails, 28V and 3.3Vaux o 12V output optional
1000W Maximum Continuous Power
95% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 3U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology
PCI_800.155
• 220VAC Continuous Input Voltage
• VITA 62.2 specification compatible
• 2300V Isolation Between Input /Output
• Active Input EMI Filtering
• Transient look ahead/cut-off technology
• 6 Voltage output Rails
• Isolated 3.3V aux standby feature
• 600W Maximum Power, NO PFC stage
• 92% Typical Efficiency
• -40°C to 85°C Rail Operating Temperature
• VITA 62 3U Form Factor
• VITA 46.11 ready
• Patent pending FourRail thermal interface
• [SMART.PSU] Technology
PCI_800.320
200V to 420V Continuous Input Voltage
Extended Voltage Safety VITA62.2 connectors
100msec hold time at 1200W (with external module)
4.200V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
12V or 28V output Voltage Rail
Isolated 3.3V aux standby feature
2.400W Maximum Continuous Power
93% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
PCI_800.111
• 10-36VDC Continuous Input Voltage • 2250V Isolation Between Input /Output • Active Input EMI Filtering • Transient forward looking/cut-off technology • 2 Voltage output Rails, 12V and 3.3Vaux • 750W Maximum Continuous Power • 95% Typical Efficiency • -40°C to 85°C Rail Operating Temperature • VITA 62 3U Form Factor • VITA 46.11 ready • Patent pending FourRail thermal interface • [SMART.PSU] Technology
PCI_800.161
• 3 phase 115VAC 400Hz Continuous Input Voltage • 10msec hold time at 1200W • 1500V Isolation Between Input /Output • Active Input EMI Filtering • Transient look ahead/cut-off technology • 2 Voltage output Rails: +28V and +3.3Vaux o +12V optional instead of 28V • 1200W Maximum Continuous Power • 92% Typical Efficiency • -40°C to 85°C Operating Temperature • VITA 62 3U Form Factor • Patent pending FourRail thermal interface
PCI_800.321
200V to 420V Continuous Input Voltage
Extended Voltage Safety VITA62.2 connectors
100msec hold time at 1000W (HOLD_UP stage internal)
4.200V Isolation Between Input /Output
Active Input EMI Filtering
Transient look ahead/cut-off technology
12V Voltage Rail
Isolated 3.3V aux standby feature
2.400W Maximum Continuous Power
90% Typical Efficiency
-40°C to 85°C Operating Temperature
VITA 62 6U Form Factor
Patent pending FourRail thermal interface
PCI_800.117
• 220-290VDC Continuous Input Voltage • 1800V Isolation Between Input /Output • Active Input EMI Filtering • Transient look ahead/cut-off technology • 4 Voltage output Rails for 12V centric systems • Isolated 3.3V aux standby feature • 850W Continuous Power • 93% Typical Efficiency • -40°C to 85°C Rail Operating Temperature • VITA 62 3U Form Factor • VITA 46.11 ready • Patent pending FourRail thermal interface • [SMART.PSU] Technology
PCI_800.317
12-36VDC Continuous Input Voltage
2250V Isolation Between Input /Output
Active Input EMI Filtering
Transient forward looking/cut-off technology
2 Voltage output Rails
2000W Maximum Continuous Power
95% Typical Efficiency
-40°C to 85°C Rail Operating Temperature
VITA 62 6U Form Factor
VITA 46.11 ready
Patent pending FourRail thermal interface
[SMART.PSU] Technology