top of page
smart-psu-chip-opt.jpg

POWER SUPPLIES

SOSA

SOSA based power products are build using tha latest SOSA standards.

PCI_800.108

PCI_800.108
  • 12-36VDC Continuous Input Voltage

  • 2250V Isolation Between Input /Output

  • Active Input EMI Filtering

  • Transient forward looking/cut-off technology

  • 2 Voltage output Rails, 28V and 3.3Vaux o 12V output optional 

  • 1000W Maximum Continuous Power

  • 95% Typical Efficiency

  • -40°C to 85°C Rail Operating Temperature

  • VITA 62 3U Form Factor

  • VITA 46.11 ready

  • Patent pending FourRail thermal interface

  • [SMART.PSU] Technology


PCI_800.155

PCI_800.155

• 220VAC Continuous Input Voltage

• VITA 62.2 specification compatible

• 2300V Isolation Between Input /Output

• Active Input EMI Filtering

• Transient look ahead/cut-off technology

• 6 Voltage output Rails

• Isolated 3.3V aux standby feature

• 600W Maximum Power, NO PFC stage

• 92% Typical Efficiency

• -40°C to 85°C Rail Operating Temperature

• VITA 62 3U Form Factor

• VITA 46.11 ready

• Patent pending FourRail thermal interface

• [SMART.PSU] Technology

PCI_800.320

PCI_800.320
  • 200V to 420V Continuous Input Voltage

  • Extended Voltage Safety VITA62.2 connectors

  • 100msec hold time at 1200W (with external module)

  • 4.200V Isolation Between Input /Output

  • Active Input EMI Filtering

  • Transient look ahead/cut-off technology

  • 12V or 28V output Voltage Rail

  • Isolated 3.3V aux standby feature

  • 2.400W Maximum Continuous Power

  • 93% Typical Efficiency

  • -40°C to 85°C Operating Temperature

  • VITA 62 6U Form Factor

  • Patent pending FourRail thermal interface

PCI_800.111

PCI_800.111

• 10-36VDC Continuous Input Voltage • 2250V Isolation Between Input /Output • Active Input EMI Filtering • Transient forward looking/cut-off technology • 2 Voltage output Rails, 12V and 3.3Vaux • 750W Maximum Continuous Power • 95% Typical Efficiency • -40°C to 85°C Rail Operating Temperature • VITA 62 3U Form Factor • VITA 46.11 ready • Patent pending FourRail thermal interface • [SMART.PSU] Technology

PCI_800.161

PCI_800.161

• 3 phase 115VAC 400Hz Continuous Input Voltage • 10msec hold time at 1200W • 1500V Isolation Between Input /Output • Active Input EMI Filtering • Transient look ahead/cut-off technology • 2 Voltage output Rails: +28V and +3.3Vaux o +12V optional instead of 28V • 1200W Maximum Continuous Power • 92% Typical Efficiency • -40°C to 85°C Operating Temperature • VITA 62 3U Form Factor • Patent pending FourRail thermal interface

PCI_800.321

PCI_800.321
  • 200V to 420V Continuous Input Voltage

  • Extended Voltage Safety VITA62.2 connectors

  • 100msec hold time at 1000W (HOLD_UP stage internal)

  • 4.200V Isolation Between Input /Output

  • Active Input EMI Filtering

  • Transient look ahead/cut-off technology

  • 12V Voltage Rail

  • Isolated 3.3V aux standby feature

  • 2.400W Maximum Continuous Power

  • 90% Typical Efficiency

  • -40°C to 85°C Operating Temperature

  • VITA 62 6U Form Factor

  • Patent pending FourRail thermal interface

PCI_800.117

PCI_800.117

• 220-290VDC Continuous Input Voltage • 1800V Isolation Between Input /Output • Active Input EMI Filtering • Transient look ahead/cut-off technology • 4 Voltage output Rails for 12V centric systems • Isolated 3.3V aux standby feature • 850W Continuous Power • 93% Typical Efficiency • -40°C to 85°C Rail Operating Temperature • VITA 62 3U Form Factor • VITA 46.11 ready • Patent pending FourRail thermal interface • [SMART.PSU] Technology

PCI_800.317

PCI_800.317
  • 12-36VDC Continuous Input Voltage

  • 2250V Isolation Between Input /Output

  • Active Input EMI Filtering

  • Transient forward looking/cut-off technology

  • 2 Voltage output Rails

  • 2000W Maximum Continuous Power

  • 95% Typical Efficiency

  • -40°C to 85°C Rail Operating Temperature

  • VITA 62 6U Form Factor

  • VITA 46.11 ready

  • Patent pending FourRail thermal interface

  •  [SMART.PSU] Technology

bottom of page